<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2d1 20170631//EN" "JATS-journalpublishing1.dtd">
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>ijesm</PublisherName>
      <JournalTitle>International Journal of Engineering, Science and</JournalTitle>
      <PISSN>I</PISSN>
      <EISSN>S</EISSN>
      <Volume-Issue>Volume 6, Issue 8,</Volume-Issue>
      <PartNumber/>
      <IssueTopic>Multidisciplinary</IssueTopic>
      <IssueLanguage>English</IssueLanguage>
      <Season>December 2017 (Special Issue)</Season>
      <SpecialIssue>N</SpecialIssue>
      <SupplementaryIssue>N</SupplementaryIssue>
      <IssueOA>Y</IssueOA>
      <PubDate>
        <Year>2017</Year>
        <Month>12</Month>
        <Day>24</Day>
      </PubDate>
      <ArticleType>Engineering, Science and Mathematics</ArticleType>
      <ArticleTitle>Effect of Pressure on Thermo Physical Properties of MixedRefrigerantR-290andR-600afor High Capacity Vapour Compression Refrigeration System (VCRS</ArticleTitle>
      <SubTitle/>
      <ArticleLanguage>English</ArticleLanguage>
      <ArticleOA>Y</ArticleOA>
      <FirstPage>496</FirstPage>
      <LastPage>502</LastPage>
      <AuthorList>
        <Author>
          <FirstName>Siddharth Kumar Nayak? Ravikiran Tadepalli?? SallooriRithwikGoud??? Vishnu</FirstName>
          <LastName>Saini</LastName>
          <AuthorLanguage>English</AuthorLanguage>
          <Affiliation/>
          <CorrespondingAuthor>N</CorrespondingAuthor>
          <ORCID/>
        </Author>
      </AuthorList>
      <DOI/>
      <Abstract>Theconceptofmixedrefrigerantfluidshasemergedduringthepastfewdecadesfrom16thcenturyduetoitssuperior thermo physical propertiesas compared tobasefluids.Itisprimarilyused ascoolantsinheattransferequipmentsuch asheatexchangers,electroniccoolingsystemandradiators.Inthepresentinvestigation,analyze thethermo physical properties,variousparametersbyconsidering10gmsof mixedrefrigerant of propaneandISO-butaneatdifferent compositions.Resultsarepresentedforsimulationscarried outatatemperaturerange of 300-350Kandapressure rangeof3MPato7MPa.It isconcludedfromtheresultsthatasthetemperatureincreases,specificheat ofmixed refrigerantdecreases.Similarly,thermal conductivityincreasewithan increaseintemperature foramixed refrigerant atdifferentcompositions. Further,asthepressureisvariedfrom3MPato7MPawhilekeepingthetemperature constant at350K,thespecificheatdecreaseby 5.2%aswell as thermal conductivityfollowsthe oppositetrendandis increasedby 6.9%.</Abstract>
      <AbstractLanguage>English</AbstractLanguage>
      <Keywords>Refrigerants, Thermophysical, Base fluids, heat transfer, Coolants, Heat exchangers</Keywords>
      <URLs>
        <Abstract>https://ijesm.co.in/ubijournal-v1copy/journals/abstract.php?article_id=4275&amp;title=Effect of Pressure on Thermo Physical Properties of MixedRefrigerantR-290andR-600afor High Capacity Vapour Compression Refrigeration System (VCRS</Abstract>
      </URLs>
      <References>
        <ReferencesarticleTitle>References</ReferencesarticleTitle>
        <ReferencesfirstPage>16</ReferencesfirstPage>
        <ReferenceslastPage>19</ReferenceslastPage>
        <References/>
      </References>
    </Journal>
  </Article>
</ArticleSet>